at the chosen size
RecommendedThree kinds of footing
A footing spreads the load of a post, column or wall over enough soil to stop it sinking. Homeowners meet three shapes most often, and each has its own volume formula.
- Round piers are cylinders, usually poured inside a cardboard form tube often called a sonotube. They carry deck posts, porch columns and pole barns.
- Square or rectangular pads are blocks of concrete under a single post or column, poured in a dug hole or a simple wooden form.
- Strip footings are long, continuous footings under a wall, a garden wall or a building's perimeter.
Convert every dimension to feet first, multiply by the number of footings, add a waste allowance, and divide by 27 for cubic yards.
A worked example: six deck piers
A deck on six 12 inch piers, each 48 inches deep. The radius is 6 inches, which is 0.5 ft, and the depth is 4 ft. One pier holds pi x 0.5 x 0.5 x 4, which is 3.14 cubic feet. Six piers hold 18.85 cubic feet. With 10 percent for waste that is 20.73 cubic feet, or 0.77 cubic yards. In 60 lb bags at 0.45 cubic feet each, that is 47 bags, and each hole takes about 7.7 bags, so you would mix 8 per hole.
A worked example: a strip footing
A 40 ft garden wall on a strip footing 16 inches wide and 12 inches deep. 1.333 ft x 40 ft x 1 ft is 53.3 cubic feet. With 10 percent waste it is 58.7 cubic feet, or 2.17 cubic yards, which rounds up to 2.25 yards of ready mix.
Sonotube sizes
Round form tubes come in standard diameters, most commonly 6, 8, 10, 12, 14, 16, 18 and 24 inches, and in 4 ft and 12 ft lengths. The calculator picks the smallest standard tube at least as wide as the pier you enter and counts the 4 ft lengths you need.
The table is handy for a quick check: a 10 inch tube 4 ft deep needs about 4 x 1.21, which is just under 5 bags of 60 lb concrete.
How deep should a footing go?
In cold climates, the bottom of every footing must sit below the frost line. Water in the soil above that line freezes and expands each winter, and a footing sitting in it gets lifted a little each year until a deck tilts or a wall cracks. Frost depth ranges from a few inches in the southern US to 48 inches and more in the northern states, and your local building department sets the figure that applies. Even in warm areas, footings need to reach firm, undisturbed soil below any topsoil or fill.
Strip footing proportions
For light walls the International Residential Code sets minimums starting at 12 inches wide and 6 inches thick, with wider footings for heavier buildings and weaker soils. Many builders work to a footing about twice as wide as the wall it carries, with the depth about equal to the wall thickness. Two continuous runs of #4 rebar near the bottom are common in strip footings. Footings for anything structural should follow your local code and, where required, an engineer's drawing.
Bags or a truck?
Under about one cubic yard, bags usually win. Ready mix plants charge a short load fee on small orders, which can cost more than the concrete itself. Above a yard, a truck is usually cheaper and saves an enormous amount of mixing. For a row of deck piers, the deciding factor is often access: a truck chute only reaches so far, and a wheelbarrow from the truck to each hole is hard work. The calculator shows both, and recommends bags under one yard.
Bag yields
Common mistakes
- Using the radius as the diameter, or the diameter as the radius, which makes the answer four times too big or too small.
- Forgetting that inches must be divided by 12 before multiplying.
- Ordering the exact volume. Holes are never perfectly round or perfectly sized, and a hole dug a little wide swallows extra concrete quickly.
- Stopping a footing above the frost line to save digging.
- Pouring on loose backfill or topsoil instead of undisturbed ground.