Plywood and Sheathing Calculator

Count the plywood or OSB sheets for a wall, a subfloor or a roof deck from its size and openings, with the total weight to haul and the nails or screws to fasten every sheet.

✓ Imperial and metric✓ Package size results✓ Private by design
01
Enter your projectWall, floor or roof deck
Waste allowance10%
0%Recommended 10%25%
02
Your resultUpdates as you type
Sheets needed 0

Fasteners0

nails or screws

Coverage0

square feet bought

Buy this0

Rounded up to whole packages.

Net area0
Per sheet0
Spare sheets0
Sheets to order0
How this was calculated
Advertisement

How many sheets you need

Plywood and OSB are sold in sheets, almost always 4 ft wide and 8 ft long, though 9, 10 and 12 ft lengths exist for tall walls. The basic count is the area to cover divided by the area of one sheet, plus an allowance for the offcuts you cannot reuse.

Sheet countSheets = (length x width minus openings) / area of one sheet x (1 + waste allowance)

A 4 x 8 sheet covers 32 square feet, a 4 x 9 covers 36, a 4 x 10 covers 40 and a 4 x 12 covers 48. Round the result up to whole sheets.

A worked example

A 24 ft long wall 12 ft high is 288 square feet. With no openings and 4 x 8 sheets, that is 288 / 32, exactly 9 sheets. With a 10 percent allowance it becomes 9.9, so the order is 10 sheets. At 1/2 inch, each sheet weighs about 46 lb, so the stack weighs about 464 lb. On studs 16 inches on center, each 4 x 8 sheet takes about 66 nails at 6 inch spacing on the edges and 12 inches in the field, so 660 fasteners in total.

Openings

Windows and doors are deducted from the wall area, but not always from the sheet count. Sheathing is usually run straight over an opening and cut out afterwards, and the offcut is rarely large enough to use anywhere else. For walls with a few small windows, deducting the openings and keeping a 10 percent allowance gives a sensible count. For a wall that is mostly glass, such as a sunroom, lay out the sheets on a sketch instead.

Choosing a thickness

Panel thickness is set by what the panel spans and what it carries. Sheathing and subfloor panels carry a span rating stamped on the face, such as 32/16 or 24 oc, which gives the maximum framing spacing the panel is rated for on a roof and on a floor.

UseCommon panelActual thicknessApprox weight, 4 x 8
Wall sheathing7/16 in OSB or 1/2 in plywood7/16 or 15/32 in45 to 46 lb
Roof deck, rafters 16 in7/16 in OSB or 1/2 in plywood7/16 or 15/32 in45 to 46 lb
Roof deck, rafters 24 in5/8 in plywood19/32 inabout 58 lb
Subfloor3/4 in tongue and groove23/32 inabout 70 lb
Shelving and jigs3/4 in plywood23/32 inabout 70 lb
Underlayment, backing1/4 in plywoodabout 7/32 inabout 23 lb

Notice the actual thickness column. Structural panels are sold by a nominal thickness and made slightly thinner: 1/2 inch plywood is usually 15/32 and 3/4 inch is 23/32. That matters when you set the depth of a dado, choose a screw length or line up a floor with an existing one.

Plywood or OSB?

Both are rated structural panels and both are accepted by building codes for sheathing and subfloor at the same span ratings. OSB is usually cheaper and more uniform, with no voids. Plywood holds fasteners a little better at the edges, tolerates getting wet and drying out better, and lies flatter after a soaking. For a subfloor that may sit open to rain during construction, many builders prefer an enhanced OSB with a sealed surface and edges, or plywood.

Fastening

The most common schedule for wall and roof sheathing is a fastener every 6 inches along the panel edges and every 12 inches along the intermediate framing members, often called the field. On a 4 x 8 sheet that is about 48 fasteners around the edges. On 16 inch framing there are two intermediate studs, which add about 18 more for roughly 66 in total. On 24 inch framing there is one, for roughly 57. Subfloors are usually glued as well as screwed or nailed on the same spacing, which stops squeaks. High wind areas and shear walls often need closer spacing, so follow the nailing schedule in your plans or local code.

Leave a gapLeave about 1/8 inch between panels at every edge and end. Wood panels swell slightly as they take on moisture, and panels butted tight can buckle. A 16d nail used as a spacer gives about the right gap.

Orientation

Lay sheathing and subfloor panels with the long 8 ft dimension running across the framing, not parallel to it. The panel is much stiffer in that direction, and the span rating assumes it. On walls, many builders run sheets vertically instead so every edge lands on a stud, which is also acceptable; check your plans if the wall is a shear wall.

Handling and hauling

Sheet goods are heavy and awkward. A stack of 10 sheets of 3/4 inch plywood weighs about 700 lb, which is more than many small pickups can safely carry, and a 4 x 8 sheet catches the wind like a sail. The total weight in the results is there so you can plan the trip, or decide to pay for delivery. Store sheets flat and off the ground on a few evenly spaced blocks so they stay flat.

Common mistakes

  • Running panels parallel to the joists on a floor, which halves their stiffness.
  • Butting panels tight with no expansion gap.
  • Lining up the joints of every row, so four corners meet at one point.
  • Buying 1/2 inch panels for a roof on 24 inch rafters, which is beyond their span rating.
  • Forgetting the extra sheets for gable ends, which are triangles and waste more than rectangles.
Advertisement
Common questions

Plywood Calculator FAQ

Straight answers to the questions people ask most about this calculation.

How many sheets of plywood do I need?

Divide the area by the area of one sheet, 32 square feet for a 4 x 8, then add about 10 percent and round up. A 24 by 12 ft wall is 288 square feet, which is 9 sheets exactly, or 10 with the allowance.

How many square feet is a sheet of plywood?

A standard 4 x 8 sheet is 32 square feet. A 4 x 9 is 36, a 4 x 10 is 40 and a 4 x 12 is 48 square feet.

How much does a sheet of plywood weigh?

About 23 lb for 1/4 inch, 46 lb for 1/2 inch and 70 lb for 3/4 inch, for a 4 x 8 sheet. Weight varies with the wood species and the moisture content.

What thickness plywood for a roof?

7/16 inch OSB or 1/2 inch plywood is common on rafters 16 inches on center, and 5/8 inch on rafters 24 inches on center. Check the span rating stamped on the panel and your local code.

What thickness plywood for a subfloor?

3/4 inch tongue and groove, which is 23/32 inch actual, is standard for joists up to 24 inches on center. It is usually glued and screwed to the joists.

How many nails per sheet of plywood?

At 6 inches on the edges and 12 inches in the field, a 4 x 8 sheet takes about 66 fasteners on 16 inch framing and about 57 on 24 inch framing.

Is OSB as strong as plywood?

For sheathing and subfloor at the same span rating, yes. Both are rated structural panels. Plywood handles getting wet and drying out better and holds edge fasteners slightly better.

Should plywood run horizontally or vertically?

On floors and roofs, run the long dimension across the joists or rafters. On walls either way is acceptable, though shear walls may specify one orientation.

Why is 3/4 inch plywood actually 23/32 inch?

Structural panels are sanded and manufactured slightly under their nominal size. 3/4 inch is 23/32 actual, 5/8 is 19/32 and 1/2 is 15/32.

Advertisement
Result 0