Solar Battery Calculator

Calculate off-grid battery storage in amp-hours and kilowatt-hours, depth of discharge, days of autonomy and solar array wattage for RV, van and cabin systems.

✓ Imperial and metric✓ Package size results✓ Private by design
01
Enter your projectDaily power consumption and battery specs
02
Your resultUpdates as you type
Battery bank capacity needed 0

Total amp-hours0

at selected system voltage

Battery modules0

individual batteries to buy

Buy this0

Rounded up to whole packages.

Usable energy required0
Battery depth of discharge0
Recommended solar array0
Solar charge controller rating0
How this was calculated
Battery Bank8.0 kWhInverter LoadAmp Hours
Live Off-Grid Battery Storage & Inverter Bus
Advertisement

Understanding off-grid battery sizing: Watt-Hours, Amp-Hours, and Usable Capacity

Designing an off-grid electrical system for an RV, camper van, remote cabin, or marine vessel requires balancing daily energy demand with reliable energy storage. Unlike grid-tied systems that use the utility company as an infinite buffer, an off-grid system relies entirely on its battery bank when the sun is not shining or generator fuel is conserved. Accurately sizing a battery bank prevents power outages and ensures you do not permanently damage expensive battery cells through excessive discharge.

Battery capacity is measured in both kilowatt-hours (kWh) and amp-hours (Ah). While appliance power consumption is expressed in Watts or kilowatt-hours, battery banks are traditionally rated in amp-hours at a specific DC voltage (typically 12V, 24V, or 48V). The relationship between the two is simple: Watt-hours equals amp-hours multiplied by system voltage (Wh = Ah x V). For example, a 100 Ah battery at 12 Volts stores 1,200 Watt-hours (1.2 kWh) of gross energy.

Off-grid battery sizing formulasUsable Wh = (Daily kWh x 1,000 / Inverter Efficiency) x Days of Autonomy

Total Bank Wh = Usable Wh / Depth of Discharge (DoD). Total Bank Ah = Total Bank Wh / System Voltage (V). Recommended Solar Array = (Daily Wh / (Winter Sun Hours x 0.75 System Derate)).

Comparing battery chemistries: LiFePO4 Lithium vs AGM Lead-Acid

The single most important variable in battery bank sizing is depth of discharge (DoD). Depth of discharge is the percentage of a battery's total rated capacity that can be safely used without degrading cell health or shortening cycle life.

Traditional lead-acid batteries, including AGM (Absorbent Glass Mat) and Gel deep-cycle batteries, should never be discharged past 50 percent of their rated capacity. Discharging an AGM battery to 80 percent or 100 percent will cause rapid sulfation, dropping its usable lifespan from 500 cycles to fewer than 150 cycles. Consequently, if you need 200 amp-hours of usable energy, an AGM battery bank must be sized at 400 amp-hours.

In contrast, modern Lithium Iron Phosphate (LiFePO4) batteries support an 80 to 90 percent depth of discharge and deliver 3,000 to 5,000 cycles. LiFePO4 batteries also maintain a steady 13.0V to 13.2V voltage curve under heavy loads, whereas lead-acid batteries suffer from Peukert effect voltage sag when running high-draw appliances like microwaves or induction cooktops.

Battery ChemistryMax Usable Depth of DischargeCycle Life (80% Capacity)Weight per 100Ah (12V)Usable Capacity per 100AhPeukert Effect / High Draw Sag
LiFePO4 Lithium80% to 90%3,500 to 5,000 cycles24 to 28 lb80 to 90 Ah (960 to 1,080 Wh)Virtually zero (steady 13.2V)
AGM Deep Cycle50%400 to 600 cycles60 to 68 lb50 Ah (600 Wh)Moderate (voltage drops under load)
Gel Cell50%500 to 700 cycles65 to 72 lb50 Ah (600 Wh)Moderate to high
Flooded Lead-Acid50%300 to 500 cycles55 to 62 lb50 Ah (600 Wh)High (requires monthly water top-up)

A worked off-grid battery bank calculation example

Suppose you are outfitting an off-grid camper van with a 12-Volt DC electrical system. Your daily appliance audit (compressor fridge, LED lights, laptop charging, water pump, and fan) totals 2.4 kWh per day (2,400 Watt-hours). You require 2 days of autonomy for stormy weather, using LiFePO4 lithium batteries and a 90 percent efficient pure sine wave inverter.

  • Daily energy including inverter losses: 2,400 Wh / 0.90 efficiency = 2,667 Wh per day.
  • Total usable energy for 2 days of autonomy: 2,667 Wh x 2 days = 5,334 usable Watt-hours.
  • Nameplate battery bank size with 80% DoD: 5,334 Wh / 0.80 = 6,668 Watt-hours (6.67 kWh).
  • Amp-hours at 12 Volts: 6,668 Wh / 12V = 556 Amp-hours.
  • Battery modules to purchase: 556 Ah / 100 Ah per module = 5.56, rounded up to 6 x 100 Ah 12V LiFePO4 batteries (or 3 x 200 Ah batteries).
  • Solar array to recharge in 4 peak sun hours: 2,667 Wh / (4.0 hours x 0.75 real-world derate) = 889 Watts, meaning a 900W to 1,000W rooftop solar array is required.

System voltage selection: 12V vs 24V vs 48V

Choosing the correct DC bus voltage is critical as system size grows. Power loss and wire heating are governed by current (Amps). Because Watts equals Volts multiplied by Amps, doubling system voltage cuts the current in half for the exact same power. A 3,000-Watt inverter running at 12 Volts draws a massive 250 Amps from the battery bank, requiring thick 4/0 AWG welding cables and heavy 300A fuses. Running that same 3,000-Watt inverter at 24 Volts draws 125 Amps (using standard 1/0 AWG wire), and at 48 Volts it draws only 62.5 Amps (using easy-to-route 4 AWG wire). As a general rule: systems under 1,500 Watts can stay 12V; systems between 1,500W and 3,000W benefit from 24V; and systems over 3,000W should almost always be built on 48V.

Advertisement
Common questions

Solar Battery Calculator FAQ

Straight answers to the questions people ask most about this calculation.

What does days of autonomy mean in off-grid solar?

Days of autonomy refers to how many consecutive days your battery bank can supply your household or camper energy needs without receiving any solar recharge, generator power, or alternator charging. A standard off-grid design allows for 2 to 3 days of autonomy to weather passing cloud cover and storms.

Why should I choose LiFePO4 lithium over AGM batteries?

LiFePO4 lithium batteries provide roughly 80 to 90 percent usable depth of discharge compared to only 50 percent for AGM, weigh 60 percent less for the same usable energy, charge up to 4 times faster, and last 3,000 to 5,000 cycles versus 400 to 600 cycles for AGM. Over a 5 to 10 year period, LiFePO4 is significantly cheaper per usable kilowatt-hour.

Can I charge lithium batteries below freezing temperatures?

No. Standard LiFePO4 batteries must never be charged when cell temperatures drop below 32 degrees Fahrenheit (0 degrees Celsius). Charging lithium cells at sub-freezing temperatures causes irreversible lithium metal plating on the anode, permanently damaging the battery and creating a fire hazard. If operating in winter, purchase batteries with built-in internal heating pads or keep the battery bank inside your heated living space.

How do I convert amp-hours to kilowatt-hours?

Multiply amp-hours by the battery voltage and divide by 1,000. For example, a 200 Ah battery operating at 12 Volts has 2,400 Watt-hours: (200 x 12) / 1,000 = 2.4 kWh. A 100 Ah battery at 48 Volts stores (100 x 48) / 1,000 = 4.8 kWh.

How many solar panels do I need to recharge my battery bank?

To recharge one day of consumed energy, divide your daily Watt-hours by your winter peak sun hours multiplied by a 0.75 real-world system derating factor. For example, if you consume 2,000 Wh per day and have 4 peak sun hours: 2,000 / (4 x 0.75) = 667 Watts of solar panels required.

What is an MPPT solar charge controller and why is it needed?

A Maximum Power Point Tracking (MPPT) controller electronically matches the higher voltage output of solar panels to the lower charging voltage required by the battery bank. MPPT controllers are 20 to 30 percent more efficient than older PWM controllers, especially in cold or overcast weather.

How do I calculate what size inverter I need?

Your inverter size is determined by the maximum peak wattage of all 120-Volt AC appliances you might run simultaneously, not your battery size. If you plan to run an 1,100W microwave, an 800W coffee maker, and 200W of electronics together, you need an inverter rated for at least 2,500 to 3,000 continuous Watts.

Can I mix old and new batteries in the same bank?

Never mix old and new batteries or batteries of different capacities, brands, or chemistries in the same bank. The newer, stronger battery will constantly discharge into the weaker battery, leading to premature failure and balancing issues. Always replace an entire battery bank at the same time.